亚洲精品乱码久久久久久不卡,在线视频一区二区免费,亚洲天堂色图在线视频,超碰Av一区=区三区,爱爱TV,久久九九青青国产精品,性爱综合网,在线第一页
            Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
            Position首頁 > Home > Industrial Safety Products > Sensor > Area Scanner
            NJ500 series obstacle avoidance laser scanner


            1726194842215581.png

            ·It is a single-line lidar based on dTOF ranging principle.

            ·It has the advantages of small size, simple use and high cost performance.

            ·Suitable for navigation, obstacle avoidance and diversification of regional monitoring scenes.


            Product specification

            product model

            Maximum detection range

            Detection accuracy

            Scanning angle

            output form

            NJ501-1570CP

            15m@70% reflectivity

            ±4mm@1sigma

            270°

            PNP

            NJ501-1570CN

            15m@70% reflectivity

            ±4mm@1sigma

            270°

            NPN

            NJ501-2570CP

            25m@70% reflectivity

            ±4mm@1sigma

            270°

            PNP

            NJ501-2570CN

            25m@70% reflectivity

            ±4mm@1sigma

            270°

            NPN

            NJ501-2570HP

            25m@70% reflectivity

            ±4mm@1sigma

            270°

            PNP

            NJ501-2570HN

            25m@70% reflectivity

            ±4mm@1sigma

            270°

            NPN

            NJ501-3570HP

            35m@70% reflectivity

            ±4mm@1sigma

            270°

            PNP

            NJ501-3570HN

            35m@70% reflectivity

            ±4mm@1sigma

            270°

            NPN

            NJ501-4070HP

            40m@70% reflectivity

            ±4mm@1sigma

            270°

            PNP

            NJ501-4070HN

            40m@70% reflectivity

            ±4mm@1sigma

            270°

            NPN

            Installation mode

            Horizontal installation mode (SZ), vertical installation mode (CZ) and protective cover installation mode (FZ)

            Power cord

            The standard is 1m, and the length of 5m can be selected.

            Programming line

            Standard gift

            explain

            The difference between NJ500 obstacle avoidance scanner C series and H series lies in:

            1. The angular resolution of C series is: 0.3°@30HZ by default, and 0.3 @ 20/25/30hz/40hz is supported; The angular resolution of H series is: 0.3°@30HZ by default, and 0.3 @ 20/25/30hz/40/50hz is supported; In contrast, the H series has an extra 50Hz motor speed.

            2. The response time of H series can be faster by scanning the same data.

            3. At the same time, the display refresh rate of objects around H series is higher.


            Laser scanner main body

             Power cordProgramming line

            1726194842215581.png

             

            1667524189836556.png


            96160.png


            technical parameter

            Angular resolution

            Measuring parameter

            Ranging radius

            15m@70% reflectivity /25m@70% reflectivity /35m@70% reflectivity /40m@70% reflectivity

            Scanning range angle

            270°

            Angular resolution

            The default value is 0.3°@30HZ, and it supports 0.3 @ 20/25/30hz/40Hz/50Hz (NJ 500 obstacle avoidance scanner C series supports 40hz at the highest and H series supports 50hz at the highest).

            Distance deviation

            ±2cm(Typical) ①

            repeatability

            ±4mm@1sigma②

            Scanning plane angle

            Pitch 0.5; Roll 0.5

            Electrical/mechanical parameters

            operating voltage

            DC9~28V

            Power-on start time

            Typical value 10s

            power consumption

            < 2w (no load at output)

            output

            PNP/NPN available (default PNP)

            outline dimension

            52mm×52mm×70mm

            Cable length

            standard 1m

            ambient temperature

            Work:-10℃ ~ 50℃ (no frost and fog in the window); Storage:-40℃ ~ 70℃

            ambient humidity

            Work: 35% RH ~ 85% RH; Storage: 35% RH ~ 95% RH

            Anti-light interference

            80000Lux

            resist the impact

            Acceleration 10g;; Pulse duration: 16ms

            Collision times: three axes, each axis is 1000 10 times.

            Vibration resistance

            Frequency 10 Hz ~ 55 Hz; Amplitude: 0.35±0.05mm

            Scanning times: 20 times for each of XYZ three axes.

            the protection grades

            IP65

            Electromagnetic compatibility

            (EMC)

            EMI

            EN61326-1:2013

            EN55011:2009+A1:2010

            EMS

            EN61326-1:2013

            EN61000-4-2:2009

            EN61000-4-3:2006+A1:2009+A2:2010

            EN61000-4-4:2004+A1:2010

            EN61000-4-6:2014

            EN61000-4-8:2010

            Configurable function

            Sector configuration

            Users can configure YB's protection zone into the required shape through configuration software.

            Response time

            67ms(2 scans) ~ ~536ms(16 scans), and the default is 67ms.

            Zone group switching

            Four groups of external input signals (INPUT1, INPUT2, INPUT3, INPUT4) realize the switching of 16 regional groups.

            Note:

            1. The measurement error of materials with different reflectivity is controlled within 2cm (typical value). The ex-factory test method: Three kinds of test pieces (black flannel, white paper and reflective sticker) are placed at different angles and the same distance (59cm) on the whole machine inspection automation fixture. The deviation between the central value of each material and the real distance is within 2 cm, and the maximum difference between the three materials is within 2 cm.

            2. 10% black velvet 600mm position measurement statistics.


            Schematic diagram of working principle and protection area configuration

            Schematic diagram of protection area 1

            Schematic diagram of protection area 2

            1726196477634861.png1726196505964341.png

            sign

            meaning

            describe

            1

            Protected area 1

            OUTPUT1 enters the OFF state when an obstacle is detected.

            2

            Protected area 2

            OUTPUT2 enters the OFF state when an obstacle is detected.

            3

            Protected area 3

            OUTPUT3 enters the OFF state when an obstacle is detected.

            Note:

            1. The measurement error of materials with different reflectivity is controlled within 2cm (typical value). The ex-factory test method: Three kinds of test pieces (black flannel, white paper and reflective sticker) are placed at different angles and the same distance (59cm) on the whole machine inspection automation fixture. The deviation between the central value of each material and the real distance is within 2 cm, and the maximum difference between the three materials is within 2 cm.

            2. 10% black velvet 600mm position measurement statistics.



            Schematic diagram of working principle and protection area configuration

            Schematic diagram of protection area 1

            Schematic diagram of protection area 2

            1726196477634861.png1726196505964341.png

            sign

            meaning

            describe

            1

            Protected area 1

            OUTPUT1 enters the OFF state when an obstacle is detected.

            2

            Protected area 2

            OUTPUT2 enters the OFF state when an obstacle is detected.

            3

            Protected area 3

            OUTPUT3 enters the OFF state when an obstacle is detected.


            Indicator light status

            1726196717891121.png

            OK: After power-on, the trouble-free OK light is always on, and the trouble-free OK light flashes.

            INPUT(1~4): lit when the input is ON, and turned OFF when the input is OFF.

            OUTPUT(1~3): lights when there is no obstacle, and turns off when there is an obstacle.

            Note: When the equipment is just powered on, all the indicator lights will enter the running water state, and the OK light will go out for 10 seconds, indicating that the equipment is starting and is in a normal state.


            Cable interface

            The configuration cable is a standard USB Type-C data cable (optional).

            See the figure below for the cable structure, and the standard cable length is 1m.

            1726196848500139.png

            colour

            signal

            describe

            blue

            0V

            working power supply

            palm

            24V

            Yellow/green

            PE

            Red/blue

            COM

            The common terminal of the regional group switching signal input, when the input signal is PNP logic, COM is connected to 0V; When the input signal is NPN logic, COM is connected to 24V.

            powder

            INPUT1

            Regional group selection signal, which can switch between regional groups through the changes of input signals of INPUT1, INPUT2, INPUT3 and INPUT4.

            green

            INPUT2

            ash

            INPUT3

            red

            INPUT4

            black

            OUTPUT1

            Three independent PNP(NPN) outputs;

            PNP transistor output; In the ON state, the load current is ≤100mA and the output voltage is ≥ VCC-2v; In the OFF state, the leakage current is ≤1mA, and the residual voltage is ≤ 1V (excluding the influence of wire extension).

            When the NPN transistor outputs, the load current is ≤100mA and the output voltage is ≤2V in the ON state; In the OFF state, the leakage current is ≤1mA and the residual voltage is ≤2V (excluding the influence of wire extension).

            The protectiON area is on when there is no object; In the OFF state when there is an object.

            white

            OUTPUT2

            purple

            OUTPUT3

            Ash/powder

            OK

            Independent PNP(NPN) output, the fault state output is OFF, and it is ON when there is no fault.


            Product dimension diagram

            1726197437255476.png


            Scanning range

            1726197507946675.png


            Installation mode

            Horizontal installation mode

            1726197845421148.png      1726197877884073.png

            Vertical installation mode

            1726197965435752.png1726198002661049.png

            Installation mode of protective cover

            1726198028335499.png1726198054130018.png
            Related Products
            Download
            PDF file download
            Video file download
            Previous

            Contact us

            400-881-6062

            Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

            E-Mail: info@lh-safety.com

            Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

            (Greenland East Coast International Plaza-Room A 313)

            Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

            Online service

            Online message

          1. Click to refresh