            D3SL-T/RFID electromagnetic locking type
            1.png

            ·Electromagnetic force locking 500N

            ·Adopt a small plane "electromagnetic" locking structure.

            ·Support 16 to 20 cascaded connections.

            ·Design of permanent magnet in matcher

            ·Small body, simple installation

            ·Full-angle eye-catching indicator light

            ·No abrasive powder will be produced.

            ·IP65/IP67 protection


            D3SL-T/RFID Series Selection Table

            Locking mode

            deploy

            model

            Output mode

            coded system

            Electromagnetic locking

            normalized form

            D3SL-T-DB-N2

            NPN

            universal coding

            D3SL-T-DB-N1

            NPN

            Unique coding

            D3SL-T-DB-P2

            PNP

            universal coding

            D3SL-T-DB-P1

            PNP

            Unique coding

            Advanced type

            D3SL-T-DG-N2

            NPN

            universal coding

            D3SL-T-DG-N1

            NPN

            Unique coding

            D3SL-T-DG-P2

            PNP

            universal coding

            D3SL-T-DG-P1

            PNP

            Unique coding


            Technical parameters of D3SL-T/RFID

            type

            Hinged door

            small-sized

            M12 connector

            normalized form

            High functional type

            working distance

            Sao(off-0n)

            4mm

            Sar(on-0ff)

            4mm

            Response time

            Lock → release

            155ms

            Release → lock

            155ms

            Detection → Non-detection

            20ms+2ms* (Number of cascaded connections -1)

            Non-detection → detection

            300ms+25ms* (Number of cascaded units -1)

            Control output

            (OSSD output)

            Output mode

            Transistor output "2

            Maximum load current

            150mA

            Residual voltage (on)

            Maximum ?2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

            OFF voltage

            Maximum ?2.0V (when the cable is 5m) and 3.0V (when the cable is 31m).

            leakage current

            Up to 0.5mA

            Maximum load capacity

            0.8uF

            Load connection resistance

            Max. 2.5 Euro

            AUX output

            (Non-safety system output)

            Output mode

            Transistor output

            Maximum load current

            50mA

            Residual voltage (ON)

            Maximum 2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

            external input

            (Short-circuit current)

            Safety input

            About 1.5 max 2

            Locking control input OSSD action switching input

            About 2.5 mA

            Reset /EDM input

            About 5mA (high functional type only)

            EDM select input

            About 2.5 mA (high functional type only)

            Power Supply 

            Power supply voltage

            24 VDC 10% including ripple (P-P)10% Class2

            consumed power

            <5W

            protective circuit

            Reverse connection protection of power supply, short circuit protection of outputs, surge protection of outputs and reverse connection protection of outputs.

            Environmental resistance

            Enclosure protection grade

            IP65/67(IEC60529)

            Operating ambient temperature

            20 degrees below zero to 55 degrees without freezing.

            Storage ambient temperature

            25 degrees below zero to 70 degrees without freezing.

            Using ambient humidity

            5% to 95%RH

            Storage environment humidity

            5% to 95%RH

            Vibration resistance

            10 to 55 Hz, double amplitude 2.0 mm, X, Y and Z directions for 5 minutes (IEC60947-5-3

            Applicable standards

            ENISO13849-1:2015(PLe,Category4), IEC60947-5-3,EN60947-5-3


            Model description of safety switch

             1728548977520914.png 



            hookup

            Standard type (NPN, cascade)

            Standard (PNP, cascade)

            1719978292858022.png

            Standard type (NPN, cascade)

            1719978426648983.png

            Standard (PNP, cascade)

            1719978725470017.png

            Functional (NPN, cascade)

            Functional (PNP, cascade)

            1719979076106539.png

            "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

            "1. Use EDM and reset: wiring as shown in the figure.

            2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V.

            3. Only use EDM: Turn off the EDM selection (pink line).

            K1.K2: External equipment (forced guided relay, electric and magnetic contactor, etc.)

            S: reset switch

            "Open and close linkage, purple is connected with +24V; Locking linkage purple disconnection

            "1. Use EDM and reset: wiring as shown in the figure.

            2. Do not use EDM and reset: connect EDM selection (pink line) and reset /EDM (light color recording) to 0V.

            3. Only use EDM: Turn off the EDM selection (pink line).

            K1.K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

            S: reset switch

            High functional type (NPN, cascade)

            1719979521976024.png

            "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

            1. Use EDM and reset: wiring as shown in the figure.

            2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V;

            3. Only use EDM: Turn off the EDM selection (pink line).

            K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

            S: reset switch

            "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

            1. Use EDM and reset: wiring as shown in the figure.

            2. Do not reset EDM: Select EDM (chalk line) and reset /EDM (light green) to+24V;

            3. EDM only: Turn off the EDM selection (chalk line).

            K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

            S: reset switch

            Functional (PNP, cascade)

            1719979875434469.png

            Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

            1. Use EDM and reset: wiring as shown in the figure.

            2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to OV;

            3. Only use EDM: Turn off the EDM selection (pink line).

            K1,K2: External equipment (forced-guided dimensional appliances, electromagnetic contactors, etc.)

            S: reset switch

            Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

            *1. Make ?EDM and reset: wire as shown in the figure.

            2. Do not reset EDM: Select EDM (chalk line) and connect reset /EDM (light green) to 0V;

            3. EDM only: Turn off the EDM selection (chalk line).

            K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

            S: reset switch


            Indication of indicator light

            1719983442751425.png


            Product ruler diagram

            1719983681983392.png


            Selection Method of Safety Switch D3SL-T/RFID Series

            1728618489514684.png



            Related Products
            Download
            PDF file download
            Video file download
            Previous

            Contact us

            400-881-6062

            Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

            E-Mail: info@lh-safety.com

            Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

            (Greenland East Coast International Plaza-Room A 313)

            Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

            Online service

            Online message

          1. Click to refresh