亚洲精品乱码久久久久久不卡,在线视频一区二区免费,亚洲天堂色图在线视频,超碰Av一区=区三区,爱爱TV,久久九九青青国产精品,性爱综合网,在线第一页
            Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
            Position首頁(yè) > Home > Industrial Safety Products > Safety Controller > Programmable safety controller
            SM 302 safety relay

                 

                 As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

            (1) Redundancy

            (2) Difference

            (3) Self-detection

                    How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.


            ▊ SM-302 programmable safety controller
            1666939573713918.png

            · Is a configurable safety controller, which supports the input of various safety product components.

            ·Maximum support for 3 sets of dual-loop inputs.

            ·Iso 13849-1 performance index PLe

            ·Built-in self-diagnosis function for fault detection

            ·Modbus protocol communication

            ·Input and output fault indicator light

            ·Safety certification: PL e, Cat: 4


            Product selection

            product name

            model

            Safety input

            Safe output

            brand

            Programmable safety controller

            SM-302

            3CH

            2NO

            LHS
            explain

            Up to 3 sets of dual-channel security products can be entered.

            The programming software defines the field safety products by itself.

            Official website programming software download connection.:http://lhsafety.com.cn/showinfo-257-118-0.html


            safety performance

            ·Performance level (PL): PLE

            ·Safety category (cat.): cat.4.

            ·Task time (TM): 20 years.

            ·Diagnostic coverage (DC/DC AVG): 99%

            ·Safety integrity level (SIL): SIL3

            ·Hardware fault margin (HFT): 1

            ·Safety Failure Score (SFF): 99%

            ·PFHD: 1.78e-9/h

            ·Stop category: 0/1               

            Comply with the standard EN ISO13849

            Comply with the standard EN ISO13849

            Comply with the standard EN ISO13849

            Comply with the standard EN ISO13849

            Comply with standards IEC61508, IEC62061.

            Comply with standards IEC61508, IEC62061.

            Comply with standards IEC61508, IEC62061.

            Comply with standards IEC61508, IEC62061.

            Comply with standard EN 60204-1.


            Main technical parameters

            Power supply characteristics

            ·Power supply voltage: 24VDC

            ·Voltage range: 20~30VDC

            ·Current loss: ≤100mA(24VDC)

            Input characteristics

            ·Input current: ≤10mA(24VDC)

            ·Conductor resistance: ≤15Ω

            ·Input equipment: emergency stop button, safety door, two-hand button,

            ·Safety light curtain, magnetic switch, etc

            ·Input channel: 3

            output characteristic

            ·Number of contacts: 2NO (safety output)

            ·Contact material: AgSnO2

            ·Contact fuse protection: 10A is fast, 6A is slow.

            ·Switching capacity: 5A/230VAC;; 5A/24VDC

            Time characteristic

            ·Suction buffer time:≤100ms

            ·Release buffer time:≤30ms

            ·Recovery time:

                     Emergency stop operation:≤30ms

                     Power failure:≤1000ms

            ·Recovery time:

                     Emergency stop operation:≤30ms

                     Power failure:≤100ms

            ·Short-term interruption of power supply:20ms

            Communication characteristics

            ·Baud rate: 38.4kbps (fixed)

            ·Communication length: ≤1000m

            ·Networking capacity: ≤10 units


            Environmental characteristic parameters

            ·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

            ·Vibration frequency: 10Hz~55Hz

            ·Vibration amplitude: 0.35mm

            ·Operating temperature: -20℃~+60℃

            ·Storage temperature: -40℃~+85℃

            ·Relative humidity: 10%~90%

            ·Overvoltage grade: Ⅲ

            ·Pollution level: 2

            ·Altitude: ≤2000m

            ·Rated isolation voltage: 250VAC.

            ·Rated impulse voltage: 6000V(1.2/50us)

            ·Insulation strength: 1500VAC for 1min.

            ·Electrical clearance and creepage distance: in accordance with EN60947-1.

            302 22.10.27處理過(guò)原圖加了影印.png


            Functional application parameters

            functional block diagram

            Typical application

            圖片3.png

            圖片4.png


            Input element: CH1 (emergency stop button); CH2 (emergency stop button); CH3 (reset button)

            Control Logic: CH1&CH2

            Reset mode: manual reset.

            Output delay: 0s

            Safety level: Cat.4 performance level: PLe safety integrity level: SIL 3


            Wiring diagram

            Power Supply 

            1.png

            correspondence

            1655948458157829.png

            input

            1655948540921377.png1655948633175148.png1655948716671157.png
            6.png7.png
            9.png10.png

            reset

            11.png12.png

            feedback

            13.png14.png

            output

            15.png

                 


            Related Products
            Download
            PDF file download
            Video file download
            Previous

            Contact us

            400-881-6062

            Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

            E-Mail: info@lh-safety.com

            Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

            (Greenland East Coast International Plaza-Room A 313)

            Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

            Online service

            Online message

          1. Click to refresh