            Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
            Position首頁 > Home > Industrial Safety Products > Safety Controller > Programmable safety controller
            SC-4 security expansion module
            SM-602 programmable safety controller

            As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

            (1) Redundancy

            (2) Difference

            (3) Self-detection


               How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.

            SC-4 security expansion module

            841056c.png

            · Is a safety relay output expansion module.

            · Receive the on-site safety switch signal, and expand it into 4 NO (normally open) safety output contacts and 2 NC (normally closed) auxiliary output contacts. 
            · Two auxiliary contacts can be used for output status indication and fault feedback respectively.

            Product selection     0523ce09f27183840accf49d6c9b5a4.png

            product name

            model

            Safety input

            Safe output

            order number

            SC-4

            24V DC

            Safety switch, contact switch

            4NO+2NC

            LHS
            explain

            Safety switch, contact switch


            safety performance

            ·Performance level (PL): PLE

            ·Safety category (cat.): cat.4.

            ·Task time (TM): 20 years.

            ·Diagnostic coverage (DC/DC AVG): 99%

            ·Safety integrity level (SIL): SIL3

            ·Hardware fault margin (HFT): 1

            ·Safety Failure Score (SFF): 99%

            ·PFHD: 1.78e-9/h

            ·Stop category: 0           

            Comply with the standard EN ISO13849

            Comply with the standard EN ISO13849

            Comply with the standard EN ISO13849

            Comply with the standard EN ISO13849

            Comply with standards IEC61508, IEC62061.

            Comply with standards IEC61508, IEC62061.

            Comply with standards IEC61508, IEC62061.

            Comply with standards IEC61508, IEC62061.

            Comply with standard EN 60204-1.


            Main technical parameters

            Power supply characteristics

            ·Power supply voltage: 24VDC

            ·Voltage range: -15%~+10%

            ·Current loss: ≤70mA(24VDC)

            Input characteristics

            ·Input current: ≤70mA(24VDC)

            ·Conductor resistance: ≤15Ω

            ·Input equipment: safety switch, contact switch.

            output characteristic

            ·Number of contacts: 4NO+2NC

                   Safety outputs: 13, 14, 23, 24, 33, 34, 43, 44.

                   Auxiliary outputs: 11, 12 (status)

                   Y1, Y2 (feedback)

            ·Contact material: AgSnO2+0.2 μm Au.

            ·Contact type: forced guidance

            ·Contact fuse protection: 10A gL/gG, NEOZED (normally open contact)

                   6A gL/gG, NEOZED (normally closed contact)

            ·Switching capacity (en 60947-5-1): AC-15, 5a/230v; DC-13, 5A/24V

            ·Mechanical life: more than 107 times

            Time characteristic

            ·Suction buffer time: ≤30ms

            ·Release buffer time: ≤20ms

            ·Recovery time: ≤1000ms

            ·Short interruption of power supply: 20ms


            Environmental characteristic parameters

            ·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

            ·Vibration frequency: 10Hz~55Hz

            ·Vibration amplitude: 0.35mm

            ·Operating temperature: -20℃~+60℃

            ·Storage temperature: -40℃~+85℃

            ·Relative humidity: 10%~90%

            ·Electrical clearance and creepage distance: in accordance with EN60947-1.

            ·Overvoltage grade: Ⅲ

            ·Pollution level: 2

            ·Altitude: ≤2000m

            ·Rated isolation voltage: 250VAC.

            ·Rated impulse voltage: 6000V(1.2/50us)

            ·Insulation strength: 1500VAC for 1min.

            841056c.png


            Functional application parameters

            functional block diagram

            Typical application

            圖片2.png

            典型應(yīng)用圖.png


            Overall dimensions (depth× height× width):

            Overall dimensions (depth× height× width):114.5mm×99.0mm×22.5mm

            Net weight of product200g

            外形尺寸圖.png


            Wiring diagram

            Power supply/input loop

            Switch input

            電路圖1.png

            Output loop

            電路圖2.png

            feedback loop

            電路圖3.png


            Related Products
            Download
            PDF file download
            Video file download
            Previous

            Contact us

            400-881-6062

            Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

            E-Mail: info@lh-safety.com

            Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

            (Greenland East Coast International Plaza-Room A 313)

            Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

            Online service

            Online message

          1. Click to refresh