亚洲精品乱码久久久久久不卡,在线视频一区二区免费,亚洲天堂色图在线视频,超碰Av一区=区三区,爱爱TV,久久九九青青国产精品,性爱综合网,在线第一页
            Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
            Position首頁(yè) > Home > Industrial Safety Products > Safety Controller > Safety PLC
            SPC series programmable safety controller

            SPC series programmable safety controller
            圖片1.png

            · Modular structure: The system adopts a combined structure of "main control module+expansion module".One main control module can connect up to 14 IO modules and 2 EN modules. It supports communication between multiple main control modules.

            · Safety inputs: up to 132, supporting digital and switching signal inputs.

            · Safety outputs: up to 84,with PNP transistor outputs.

            · Function blocks: up to 255 basic logic operation blocks and specific function blocks can be used. The basic logic operation blocks include AND,OR,NOT,XOR,XNOR,RS trigger,and delay function blocks.The specific function blocks include encoder monitoring,radar monitoring,emergency stop monitoring, switch monitoring,reset, light curtain monitoring, two-hand monitoring,mode selection monitoring and EDM.

            · Encoder interfaces:Up to 12, supporting:A/B incremental encoders(maximum frequency 500KHz),sine-cosine incremental encoders(maximum frequency 120KHz),and SSI encoders(maximum baud rate 500KHz).

            · Communication interfaces:Supporting Ethernet, CAN, RS485 and Type C


            Model specification

            Product selection

            Type

            Number of inputs/channels

            Number of outputs/channels

            Communication

            Maximum quantity

            SPC-1000-AGV

            Main control module

            12

            8

            ETH、CAN、

            Type C

            1

            SPC-1000

            20

            8

            ETH、RS485

            Type C

            1

            SPC-SIO8

            Expansion module

            8

            4

            -

            14

            SPC-SIO12

            0

            0

            -

            2


            Technical parameter

            Safety parameter

            Safety integrity level

            SIL 3(IEC 61508 、IEC 62061)

            Safety performance level

            PL e(ISO 13849-1)

            Architecture category

            Cat.4(ISO 13849-1)

            PFHD

            <10-7

            TM(Continuous operating time)

            20 years(ISO 13849-1)

            Electrical parameters

            System power supply(V+ 、V-)

            24V DC(70%~ 125%)

            Output power supply(DC24V 、0V)

            24V DC(70%~ 125%)

            Power consumption(no load)

            MC12:5.5W

            MC20:3.5W

            IO:2.5W

            EN:3W

            Overvoltage category

            Class Ⅱ(EN 61131-2)

            Power-on start-up time

            ≤15s

            Response time

            Tmin=4ms ,see the hardware manual for details

            Safety input

            ON state:input voltage:13~28V

            OFF state :input voltage:0~5V

             

             

            safety output

            Output type:PNP semiconductor

            ON state:output voltage DC24V,rated current 300mA ,Output voltage drop≤2V

            OFF state : Residual voltage ≤1V , leakage current ≤0.5mA

            Maximum capacitive load:0.9uf

            Data communication

            CAN 、RS485 、Ethernet communication

            Configuration interface

            Type C 、ETH

            Display screen

            1.54 inches OLED

            Environmental parameters

            Operating temperature and humidity

            Open environment:-25℃~60℃

            Relative humidity 10%~95% ,No condensation

            Storage temperature and humidity

            -25℃~70℃

            Relative humidity 10%~95% ,No condensation

            Shock resistance

            15g,11ms Half sine wave(EN 61131-2)

             

            Vibration resistance

            5Hz~8.4Hz ,3.5mm,displacement,Constant amplitude;

            8.4Hz~150Hz ,1g acceleration,Constant amplitude(EN 61131-2)

            Protection level

            IP20(EN 60529)

            Insulation protection

            Class Ⅲ(SELV)(EN 61131-2)

            EMC

            EN 61131-2 、IEC 61326-3-1

            Environmental requirements

            RoHS 10 items

            Flame retardancy

            UL94-V1


            Product dimension diagram

            圖片2.png


            Wiring diagram

            System power supply:

            1754359937326226.png

            Emergencey stop button:

            1754359955995980.png

            Two-hand button:

            1754359969647925.png

            Light curtain:

            1754359986695893.png

            Reset:

            1754360003372869.png

            Safety output and EDM:

            1754360020919161.png1754360040745092.png




            Related Products
            Download
            PDF file download
            Video file download
            Previous

            Contact us

            400-881-6062

            Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

            E-Mail: info@lh-safety.com

            Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

            (Greenland East Coast International Plaza-Room A 313)

            Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

            Online service

            Online message

          1. Click to refresh