亚洲精品乱码久久久久久不卡,在线视频一区二区免费,亚洲天堂色图在线视频,超碰Av一区=区三区,爱爱TV,久久九九青青国产精品,性爱综合网,在线第一页
            Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
            Position首頁 > Home > Industrial Safety Products > Sensor > Laser Distance Sensor > 激光測距傳感器 短距離(1)
            Laser displacement sensor short distance
            1725513652834177.png

            ·5 micron repetition accuracy

            ·Bring your own 485 communication

            ·Accurately detect the relative displacement of the object to be measured.

            ·Used for measuring physical quantities such as length, distance, vibration, speed and orientation.


            Product introduction

            Micron-scale repetition accuracy

            Tested by laser interferometer, the repeatability is 5Um.

            485 communication

            Support 485 communication, which can replace imported brands.

            Non-contact measurement

            Non-contact measurement, metal and plastic can be detected.

            Ultra high precision

            Ultra-high precision, can measure tiny objects.


            usage scenario

            Laser displacement sensor is suitable for lithium battery, printing and packaging, coating machine, intelligent manufacturing and other industries, and is often used to measure physical quantities such as length, height, width, distance, vibration, speed, orientation, object presence, shape and flatness.


            Product parameter

            Product parameterMeasuring center 30mm typeMeasuring center 50mm typeMeasuring center 100mm typeMeasuring center 200mm typeMeasuring center 400mm type

            Model name (Note 2)

            NPN output

            LDS-H030NA

            LDS-H050NA

            LDS-H100NA

            LDS-H200NA

            LDS-H400NA

            LDS-H030N-C

            LDS-H050N-C

            LDS-H100N-C

            LDS-H200N-C

            LDS-H400N-C

            PNP output

            LDS-H030PA

            LDS-H050PA

            LDS-H100PA

            LDS-H200PA

            LDS-H400PA

            LDS-H030P-C

            LDS-H050P-C

            LDS-H100P-C

            LDS-H200P-C

            LDS-H400P-C

            Measuring center distance30mm50mm100mm200mm400mm
            measuring range±5mm±15mm±35mm±80mm±200mm
            repeatability5μm20μm40μm100μm300μm(measure a distance 200-400mm)
            600μm(measure a distance 400-600mm)
            Black and white surface error10μm40μm100μm300μm1mm
            linearity±0.1%F.S.±0.2%F.S.±0.3%F.S.

            Measuring speed

            100-2000Hz

            Communication output

            RS-485

            Laser wavelength

            Red semiconductor laser, class 2 [JIS/IEC/GB/FDA] Maximum output: 1mW, wavelength of emission peak. :650nm

            Beam diameter

            appointment Φ100μm
            appointment Φ180μm
            appointment Φ250μm
            appointment Φ400μm
            appointment Φ700μm

            Temperature characteristics

            0.03%F.S./°C

            light source

            Red semiconductor laser Class 2 (JIS/IEC/GB)/Class II (FDA) (Note 3)

            Maximum output: 1mW, wavelength of luminous beam: 655nm.

            Power supply voltage

            12V~24V DC±10% pulsation P-P10%

            Consumption current

            Less than 40mA (when the power supply voltage is 24V DC) and less than 60mA (when the power supply voltage is 12V DC).

            Control output

            <NPN output type >

            NPN open collector transistor

            Maximum inflow current: 50mA

            Applied voltage: below 30V DC (control output is between -0V).

            Residual voltage: less than 1.5V (with inflow current of 50mA)

            Leakage current: less than 0.1mA


            <PNP output type >

            PNP open collector transistor

            Maximum source current: 50mA

            Applied voltage: below 30V DC (between-+V for control output)

            Residual voltage: less than 1.5V (with an outflow current of 50mA)

            Leakage current: less than 0.1mA

            Output action

            ON in light/on in non-light can be switched.

            Short circuit protection

            Equipped (automatic recovery type)

            analog output

            Output range: 0v ~ 5v (++5.2V in case of alarm)

            Output impedance: 100 ω

            Reaction time

            0.5ms/1ms/1.5ms/5ms/10ms

            external input

             <NPN output type >

            NPN contactless input

            Input conditions

            Invalid:+8V ~+V DC or open

            Effective: 0v ~+1.2vdc.

            Input impedance: about 10kΩ.

            < <PNP output type >

            PNP contactless input

            Input conditions

            Invalid: 0v ~+0.6vdc or open.

            Effective:+4v ~+vdc

            Input impedance: about 10kΩ.

            Protective structure

            IP67(IEC)

            Degree of fouling

            2

            Operating ambient temperature

            -10℃ ~ +50℃

            Use ambient illumination

            Shouguang surface illumination 3000Lux below

            Using ambient humidity

            35%~85%RH

            Use elevation

            2,000m below

            electric cable

            belt 0.2mm2 5-core composite cable 2m

            texture of wood

            Body shell: aluminum casting front cover: propylene-based.

            weight

            Body shell: aluminum casting front cover: propylene-based.

            Applicable specifications

            Comply with EMC directives and FDA rules.

            (Note 1): When the measurement conditions are not specified, the use conditions are as follows: power supply voltage: 24V DC, ambient temperature:+20℃, reaction time: 10ms, and analog output value of measurement center distance. Object: white ceramics.

            (Note 2): Model A is analog voltage version, and Model -C is communication version.

            (Note 3): According to Laser Notice No.50 in FDA rules, abide by FDA rules.




            Product outline dimension diagram

            Related Products
            Download
            PDF file download
            Video file download
            Previous

            Contact us

            400-881-6062

            Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

            E-Mail: info@lh-safety.com

            Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

            (Greenland East Coast International Plaza-Room A 313)

            Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

            Online service

            Online message

          1. Click to refresh