亚洲精品乱码久久久久久不卡,在线视频一区二区免费,亚洲天堂色图在线视频,超碰Av一区=区三区,爱爱TV,久久九九青青国产精品,性爱综合网,在线第一页
            Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
            Position首頁 > Home > Industrial Safety Products > Sensor > Laser Distance Sensor > 激光測距傳感器 1-200米(1)
            LGY-200 long-distance laser ranging sensor 200 met
            1726048288130717.png


            ·Visible red laser, easy to align and debug

            ·Support the movement speed of 10m/s.

            ·Support SSI, PROFINET, MODBUS RTU, RS422 and other interface outputs.

            ·TOF measurement principle ensures ultra-fast measurement speed and ultra-fast measurement frequency.

            ·High precision, which can better locate the position of moving objects accurately.



            Product selection table

            working distance

            precision

            frequency

            joggle/interface

            Working temperature

            model

            0.2-100m

            ±2mm

            200Hz

            RS422

            –10℃...+50℃

            LGY-200-S

            200Hz

            MODBUS RTU, RS232

            LGY-200-MS

            400Hz

            SSI, RS232

            LGY-200-ES

            400Hz

            PROFINET, RS232

            LGY-200-NS

            200Hz

            RS422

            –40℃...+50 ℃

            LGY-200H-S

            200Hz

            MODBUS RTU, RS232

            LGY-200H-MS

            400Hz

            SSI, RS232

            LGY-200H-ES

            400Hz

            PROFINET, RS232

            LGY-200H-NS


            technical parameter

            performance parameter

            measuring range

            0.2…200m

            precision

            ±2mm(90%reflectivity)@2σ

            repeatability

            0.3mm

            Measuring frequency

            200Hz

            resolution ratio

            0.1mm

            Measuring object

            Reflective film

            Laser spot

            6mm(10m)

            Laser light source

            Red laser

            wavelength:650–690nm

            Pulse duration:3ns

            Beam divergence:0.16×0.6mrad

            Laser power:0.95mW

            Laser grade

            Secondary laser


            IEC 60825-1:2014, EN 60825-1:2014


            Laser lifetime

            100'000h @ 25℃


            Interface parameters

            PROFINET

            Network load level

             II

            function

            Measurement data output, parameter setting

            RS-232

            Baud rate

            115200

            data bit

            8

            Stop position

            1

            Check Digit

            fluid control

            function

            Measurement data output, parameter setting

            Mechanical/electronic parameters

            supply voltage

            DC 18V…30V

            power

            <3.5W (在24VDC)

            Initialization time

            Typ. 5s

            Connection type

            A code 5-pin M12 plug

            sheathing material

            D-coded 4-pin M12 plug

            Aluminum die casting

            the protection grades

            IP65

            weight

            975g

            measure

            129*69.5*92mm

            Working temperature

            -10℃…+50℃

            Storage temperature

            -25℃…+75℃

            Electromagnetic compatibility (wireless)

            EN 55032:2015,EN61000-3-2:2014,EN 61000-3-3:2013,

            EN 55035:2017


            Schematic diagram of pin distribution and wiring

            1727666167173632.png1727666271945721.png


            Error code description

            If there is an error code not listed in the table below, please contact our technical support.

            serial number

            format

            meaning

            debugging

            1

            @E203

            Wrong command or parameter

            Check input instructions, parameters and communication settings.

            2

            @E220

            Communication error

            Check and eliminate electromagnetic interference around sensors and communication lines.

            3

            @E234

            no to scale

            Adjust the distance of the measured target to make it within the measuring range.

            4

            @E252

            The temperature is too high

            Reduce the ambient temperature. If an error occurs at room temperature, please contact our technical support

            5

            @E253

            The temperature is too low.

            Raise the ambient temperature. For sensors with heating function, wait for the heating temperature to rise. If an error occurs at room temperature, please contact our technical support

            6

            @E255

            The received signal is too weak

            Improve the reflectivity of the measured target.

            7

            @E256

            The received signal is too strong

            Reduce the reflectivity of the measured target.

            8

            @E257

            The background light is too noisy

            Eliminate the clutter of background light

            9

            @E260

            There are multiple targets in the measurement, so it is impossible to measure the distance.

            Determine the distance of the measured target and eliminate the phenomenon of target distance jump.

            10

            @E289

            Contact our technical support.

            /


            Sensor indicator description

            The sensor status and PROFINET interface status are displayed by LED lights as described in the following table.

            LED

            explain

            Possible cause of abnormality

            debugging

            Port2

            PROFINET interface 2

            LED lights green: normal operation

            LED off: the connection is disconnected.

            The device did not shake hands with the master station.

            The sensor is damaged.

            Contact our technical support.

            Port1

            PROFINET interface 1

            LED lights green: normal operation

            LED off: the connection is disconnected.

            The device did not shake hands with the master station.

            The sensor is damaged.

            Contact our technical support.

            Power(Error)

            Sensor status

            The LED lights green: the sensor is normal.

            The LED is red: the sensor is abnormal.

            Not running.

            The sensor is damaged.

            Check the operating voltage.

            Check the corresponding error code and eliminate the exception as instructed.

            Contact our technical support.


            Product outline dimension diagram


            1725588876571101.png


            Related Products
            Download
            PDF file download
            Video file download
            Previous

            Contact us

            400-881-6062

            Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

            E-Mail: info@lh-safety.com

            Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

            (Greenland East Coast International Plaza-Room A 313)

            Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

            Online service

            Online message

          1. Click to refresh