亚洲精品乱码久久久久久不卡,在线视频一区二区免费,亚洲天堂色图在线视频,超碰Av一区=区三区,爱爱TV,久久九九青青国产精品,性爱综合网,在线第一页
            Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
            Position首頁 > Home > Industrial Safety Products > Safety interlock switch > Magnetic induction switch
            LMC3-52 magnetic induction safety switch
            圖片1.png

            ·Miniaturized design,(compatible with 30mm aluminum frames) for easy installation.

            ·Adopts redundant internal circuits(dual CPU mutual inspection)and self-diagnostic function.

            ·Intelligent diagnosis and status display:Integrated LED indicators,provide real-time feedback on door switch status and fault information, facilitating quick troubleshooting.

            ·Support series connection of multiple switches(up to 30 switches can be connected),adapting to complex equipment layouts.

            ·The actuator coding function has low-level and high-level settings. It performs self-learning to match the sensor during initial installation. The high level function is unique and non-interchangeable.

            ·Equipped with magnetic latching function,with a magnetic holding force of up-to 15N,which can replace door magnets.


            395181ccb7a771e30162f6415dc922a.png

            Selection catagory

            Configuration type

            Coding type

            Output mode

            Lead wire mode

            Direct outlet

            Cable length

            Model

            Basic function

            Universal coding

            NPN

            Direct outlet

            3M

            LMC3-52-J2-N-Z3

            5M

            LMC3-52-J2-N-Z5

            10M

            LMC3-52-J2-N-Z10

            M12 Connector

            /

            LMC3-52-J2-N-M12

            PNP

            Direct outlet

            3M

            LMC3-52-J2-P-Z3

            5M

            LMC3-52-J2-P-Z5

            10M

            LMC3-52-J2-P-Z10

            M12 Connector

            /

            LMC3-52-J2-P-M12

            Unique coding

            NPN

            Direct outlet

            3M

            LMC3-52-J1-N-Z3

            5M

            LMC3-52-J1-N-Z5

            10M

            LMC3-52-J1-N-Z10

            M12 Connector

            /

            LMC3-52-J1-N-M12

            PNP

            Direct outlet

            3M

            LMC3-52-J1-P-Z3

            5M

            LMC3-52-J1-P-Z5

            10M

            LMC3-52-J1-P-Z10

            M12 Connector

            /

            LMC3-52-J1-P-M12

            Standard

            Universal coding

            NPN

            Direct outlet

            3M

            LMC3-52-B2-N-Z3

            5M

            LMC3-52-B2-N-Z5

            10M

            LMC3-52-B2-N-Z10

            M12 Connector

            /

            LMC3-52-B2-N-M12

            PNP

            Direct outlet

            3M

            LMC3-52-B2-P-Z3

            5M

            LMC3-52-B2-P-Z5

            10M

            LMC3-52-B2-P-Z10

            M12 Connector

            /

            LMC3-52-B2-P-M12

            Unique coding

            NPN

            Direct outlet

            3M

            LMC3-52-B1-N-Z3

            5M

            LMC3-52-B1-N-Z5

            10M

            LMC3-52-B1-N-Z10

            M12 Connector

            /

            LMC3-52-B1-N-M12

            PNP

            Direct outlet

            3M

            LMC3-52-B1-P-Z3

            5M

            LMC3-52-B1-P-Z5

            10M

            LMC3-52-B1-P-Z10

            M12 Connector

            /

            LMC3-52-B1-P-M12

            High-function typle


            Universal coding

            NPN

            Direct outlet

            3M

            LMC3-52-G2-N-Z3

            5M

            LMC3-52-G2-N-Z5

            10M

            LMC3-52-G2-N-Z10

            M12 Connector

            /

            LMC3-52-G2-N-M12

            PNP

            Direct outlet

            3M

            LMC3-52-G2-P-Z3

            5M

            LMC3-52-G2-P-Z5

            10M

            LMC3-52-G2-P-Z10

            M12 Connector

            /

            LMC3-52-G2-P-M12

            Unique coding

            NPN

            Direct outlet

            3M

            LMC3-52-G1-N-Z3

            5M

            LMC3-52-G1-N-Z5

            10M

            LMC3-52-G1-N-Z10

            M12 Connector

            /

            LMC3-52-G1-N-M12

            PNP

            Direct outlet

            3M

            LMC3-52-G1-P-Z3

            5M

            LMC3-52-G1-P-Z5

            10M

            LMC3-52-G1-P-Z10

            M12 Connector

            /

            LMC3-52-G1-P-M12


            395181ccb7a771e30162f6415dc922a.pngModel description

            1750041376195449.png



            395181ccb7a771e30162f6415dc922a.pngM12 Connection cable selection

            M12 connection cable

            image.png

            Basic function cable(5-pin, 5-core)

            LMC3-52--XL-P55C3

            LMC3-52-XL-P55C5

            LMC3-52-XL-P55C10

            Standard-type cable(8-pin,8-core)

            LMC3-52-XL-P88C3

            LMC3-52-XL-P88C5

            LMC3-52-XL-P88C10

            High-function type cable(12-pin,10-core)

            LMC3-52-XL-P1210C3

            LMC3-52-XL-P1210C5

            LMC3-52-XL-P1210C10


            395181ccb7a771e30162f6415dc922a.pngIndicator light description

            image.png


            Indicator light name

            Light color

            Status

            Status description

            Status of OSSD

            Detection status of the actuator

            Large indicator light

            Green

            Light up

            In normal operation

            ON

            Detection status

            Green

            Flashing

            (high- speed)

            Switching coding level from low to high, or teaching the matcher

            OFF

            Detected matcher is incorrect

            Green

            Flashing

            Switching coding level from low to high, or teaching the matcher

            OFF

            Detected matcher is incorrect。

            Red and green alternating

            Flashing

            (high- speed)


            An untaught actuator is detected when operating at "high" coding level

            OFF

            Detected matcher is incorrect

            Error during coding level switching

            Not fixed

            Red

            Light up

            Door is in open state.

            OFF

            Non-detection status

            Flashing

            (high- speed)


            Error state.The sensor detects an abnormality

            OFF

            Not fixed

            Turn off

            Power OFF

            OFF

            Not fixed

            OSSD indictor light

            Green

            Light up

            OSSD is on

            ON

            Detection status

            Flashing

            OSSD is on,but the door is in an unstable state such as half-open

            ON

            Detection status

            Red

            Light up

            OSSD is off

            OFF

            Not fixed

            Input indicator light

            Green

            Light up

            Safety input is on

            Not fixed

            Detection status

            Flashing

            Self- holding release waiting state(waiting for reset input)

            OFF

            Not fixed

            Turn off


            Safety input is OFF,or other states.

            OFF

            Detection status


            395181ccb7a771e30162f6415dc922a.pngTechnical parameter

            Model

            LMC3-52-J

            LMC3-52-B

            LMC3-52-G

            Type

            Basic function type

            Standard type

            High-function type

            Detection distance


            Front side

            sao(OFF→ON)

            10mm

            sar(ON→OFF

            18mm

            Side face

            sao(OFF→ON)

            6mm

            sar(ON→OFF

            14mm

            Response time(ms)*1

            Detection action

            Detection→Non-detection

            20ms+2ms×(total number of cascade-connected units -1)

            Non-detection→ Detection

            30ms+25ms×(total number of cascade-connected units-1)

            Door operation

            Allowable operating frequency

            3Hz

            Magnetic attraction

            Magnetic holding force

            15N

            Cascade connection

            Standard

            -

            Maximum 30 units

            Control output(OSSD output)

            Output type

            Transistor output×2

            Maximum load current

            PNP:<=150mA、NPN:<=100mA

            Residual voltage during ON state

            Maximum 2.5V(with 5m cable)

            Voltage in OFF state

            Maximum 2.0V(with 5m cable)

            Leakage current

            Maximum 0.5mA

            Maximum load capacity

            2.2μF

            Load wiring resistance

            Maximum 2.5Ω

            Detection distance

            Front side

            sao(OFF→ON)

            10mm

            sar(ON→OFF

            18mm

            Side face

            sao(OFF→ON)

            6mm

            sar(ON→OFF

            14mm

            Response time(ms)*1

            Detection action

            Detection→Non-detection

            20ms+2ms×(total number of cascade-connected units-1 )

            Non-detection→ Detection

            30ms+25ms×(total number of cascade-connected units-1 )

            Door operation

            Allowable operating frequency

            3Hz

            Magnetic attraction

            Magnetic holding force

            15N

            Cascade connection

            Standard

            -

            Maximum 30 units

            Control output(OSSD output)

            Output type

            Transistor output×2

            Maximum load current

            PNP:<=150mA、NPN:<=100mA

            Residual voltage during ON state

            Maximum 2.5V(with 5m cable)

            Voltage in OFF state

            Maximum 2.0V(with 5m cable)

            Leakage current

            Maximum 0.5mA

            Maximum load capacity

            2.2μF

            Load wiring resistance

            Maximum 2.5Ω

            AUX output(Non-safety system output)

            Output type

            Transistor output

            Number of outputs

            1

            Maximum load current

            50mA

            Residual voltage during ON state

            Maximum 2.5V(with 5m cable)

            External input (Short-circuit current)

            Safety input

            -

            Approximately 1.5mA×2

            Reset/EDM Input

            -

            Approximately 5mA×1

            Power supply

            Power supply voltage

            24VDC±20% including ripple(P-P)10%Class2

            Power comsuption

            0.8W*2

            Protection circuits

            Power reverse connection protection、each output short-circuit protection、eacn output surge protection、output reverse connection protection

            Safety related parameters

            ISO13849-1 IEC/EN60947-5-1 IEC/EN60947-5-3

            Compliant with ISO 13849-1 catagory 4 switch /suitable for PLe/PLd

            MTTFd≥30 years

            CE

            Environmental resistance

            Enclosure protection class

            IP65,IP67IP68 requires customization,pls consult the sales department before placing an order

            Operating ambient temperature

            -20℃ to +55℃(No freezing)

            Storage ambient temperature

            -25℃ to +70℃(No freezing)*3

            Operating ambient humidity

            5% to 95%RH

            Storage ambient humidity

            5% to 95%RH

            Vibration resistance

            10 to 55HZ、double amplitude 3.0mm、5 minutes for each directions X、Y、Z

            (IEC60947-5-3)

            Shock resistance

            30G,6 times for each direction X、Y、Z(IEC60947-5-3)

            Material

            Sensor

            Host server

            Housing

            Flame-retardant grade thermoplastic

            Cable

            PVC

            Matcher

            Housing

            Flame-retardant grade thermoplastic

            *1 The risk time specified in IEC60947-5-3 is 150 ms+2 ms×(total number of cascade-connected units-1) 

            *2 Excluding load current。

            *3 For long-term storage ,pls store in an environment below 55℃

            395181ccb7a771e30162f6415dc922a.pngProduct dimension drawing

            1750041793170171.png1750041831401457.png


            395181ccb7a771e30162f6415dc922a.pngWiring diagram

            1750042721223258.png

            Pin number

            Signal definition

            Color

            Description

            1

            24V

            Brown

            Positive power supply

            2

            OSSD2

            White

            safety output 2

            3

            0V

            Blue

            Negative power supply

            4

            OSSD1

            Black

            safety output 1

            5

            AUX output

            Gray

            Auxiliary output 1


            1750042818626171.png

            Pin number

            Signal definition

            Color

            Description

            1

            AUX output 1

            Gray

            Auxiliary output 1

            2

            24V

            Brown

            Positive power supply

            3

            Not used

            Red

            Not used

            4

            safety input 2

            Yellow

            Cascade input 2

            5

            OSSD1

            Black

            safety output 1

            6

            OSSD2

            White

            safety output 2

            7

            0V

            Blue

            Negative power supply

            8

            safety input 1

            Green

            Cascade input 1


            1750043082195521.png

            Pin number

            Signal definition

            Color

            Description

            1

            24V

            Brown

            Positive power supply

            2

            Safety input 1

            Green

            cascade input 1

            3

            0V

            Blue

            Negative power supply

            4

            OSSD1

            Black

            Safety output 1

            5

            AUX output1

            Gray

            Auxiliary output 1

            6

            Safety input 2

            Yellow

            cascade input 2

            7

            OSSD2

            White

            Safety output 2

            8

            Self-holding/EDM selection input

            Pink

            Self-holding/EDM selection input

            9

            Not used

            Red

            Not used

            10

            11

            Reset/EDM input

            Purple

            Reset/EDM input

            12

            1750045067392088.png1750045195573398.png1750045324661430.png
            Wiring example for cascade connection

            High-functioning self-protection function:

            圖片3.png

            The self-protection function is a feature that prevents the OSSD from automatically switching from OFF state to ON state. This function can prevent accidental startup or restart of the device. To restore from the state where the self-protection is active to the normal operating state, a reset operation is required.

            The basic function type and standard type can not set the self-protection function. The self-protection function is fixed to "Automatic"

            The self-protection function of high-function type can be selected from two types:"Automatic"and"Manual".

            "Automatic"and"Manual" here refer to following actions:

            Automatic:

            When the OSSD meets the condition for switching to the ON state(for example, the door is in the closed state), it shall switch to the ON state immediately.

            Manual:

            Even if the OSSD meets the condition for switching to the ON state, it shall remain in the OFF state(self-holding state).

            <Release of self-holding state>

            To switch the OSSD to the ON state and start the equipment, a reset operation must be performed under the conditions that the door with GS(non-contact)installed is closed and the equipment is ready for startup.Through this,the OSSD will switch to the ON state,and the self-holding state can be released.

            Setting of Self-holding function

            Self-holding function

            EDM function

            Reset/EDM input(Purple)

            Self-holding/EDM function selection input(Pink)

            Automatic

            Not in use

            0V

            0V

            Automatic

            in use

            Connect to 24 V via NC contact of relay

            Open

            Manual

            Not in use

            Connect to 24 V via NO reset switch

            Connect to 24 V

            Manual

            in use

            Connect to 24V via NO reset switch and NC contact of relay

            Connect to 24 V



            Related Products
            Download
            PDF file download
            Video file download
            Previous

            Contact us

            400-881-6062

            Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

            E-Mail: info@lh-safety.com

            Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

            (Greenland East Coast International Plaza-Room A 313)

            Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

            Online service

            Online message

          1. Click to refresh