亚洲精品乱码久久久久久不卡,在线视频一区二区免费,亚洲天堂色图在线视频,超碰Av一区=区三区,爱爱TV,久久九九青青国产精品,性爱综合网,在线第一页
            Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
            Position首頁 > Home > Industrial Safety Products > Safety interlock switch > Magnetic induction switch
            LMC3-50 series RFID safety door switch

            1706678051308494.pngimage.png

            With detection confidentiality (unique code can be provided)

            ?Strong anti-interference, safety and reliability.

            ?Safety level PLe can be achieved by using safe dual-channel output technology.

            ?Effectively prevent false positives or false negatives, or artificial abnormal triggers.

            ?Can be used with the safety door.


            395181ccb7a771e30162f6415dc922a.png

            Ordering information

            86b9d0315b563dc534da6381bf695f3.png

            Switch model

            Specification

            Output method

            Encoding method

            LMC3-50-40SNT/5M


            4-core direct wiring with dual output
            5M cable


            NPN

            Universal encoding

            LMC3-50-40SN1/5M

            Unique encoding

            LMC3-50-40SPT/5M

            4-core direct wiring with dual output
            5M cable


            PNP

            Universal encoding

            LMC3-50-40SP1/5M

            Unique encoding

            LMC3-50-60JNT/5M

            6-core direct wiring with dual output and cascading 5M cable

            NPN

            Universal encoding

            LMC3-50-60JN1/5M

            Unique encoding

            LMC3-50-60JPT/5M

            6-core direct wiring with dual output and cascading 5M cable

            PNP

            Universal encoding

            LMC3-50-60JP1/5M

            Unique encoding

            395181ccb7a771e30162f6415dc922a.png

            Model Description


            395181ccb7a771e30162f6415dc922a.png

            Technical parameter

            Safty standard

            Mean Time to Dangerous Failure (MTTFd) (years)

            ISO13849-11EC/EN60947-5-1IEC/EN60947-5-3

            ≥30 years

            Safety classification

            Class 4 switch according to IS0 13849-1/suitable for PLe/PL

            Certification

            CE

            Horizontal working distance

            Conduction, min:10mm

            Vertical working distance

            Conduction, min:8mm

            Operating voltage

            24V DC±15%

            Operating current

            150mA

            Response time

            60ms

            The protection grades

            IP65, IP67 (customized)

            Operating frequency

            lHZ

            Working temperature

            -10~+55℃

            Relative humidity

            5%~95%

            Material

            Flame-retardant thermoplastic


            395181ccb7a771e30162f6415dc922a.png

            Shape and installation dimensions

            尺寸圖.pngLMC3-50.png


            395181ccb7a771e30162f6415dc922a.png

            Approach pattern of LMC3-50 switch

            1706679390304986.png1706679459242220.png


            395181ccb7a771e30162f6415dc922a.pngLMC3-50 switch induction distance


            Misalignment deviation

            breakover

            disconnect

            Alignment signal

            Horizontal alignment

            The deviation is within 4 mm in the X direction.Y direction induction 0~10mmY direction induction distance > 25mmLMC3-50.png
            The deviation is > 5mm and < -5mm in the x direction.Not recommended

            Vertical alignment

            The deviation is within 4mm of soil in X direction.Z direction induction distance 0~8mmZ direction induction distance > 23mmLMC3-510.png
            The deviation is > 5mm and < -5mm in the x direction.Not recommended


            395181ccb7a771e30162f6415dc922a.png

            Hookup

            Two-way output with cascade connection diagram

            serial number

            Signal definition

            colour

            explain

            1706680404188780.png

            1

            24V

            palm

            Power supply positive

            2

            0V

            blue

            Negative power supply

            3

            output1

            black

            Safety output 1

            4

            output2

            white

            Safety output 2

            5

            input1

            green

            Cascade input 1

            6

            input2

            yellow

            Cascade input 2


            395181ccb7a771e30162f6415dc922a.pngLegend of connection between RFID switch and safety relay module (dual output)


            接線圖.png



            395181ccb7a771e30162f6415dc922a.png

            RFID switch approach pattern

            Led display

            Signal state

            State description

            input

            output

            The red light is always on.

            Yes/No.

            break

            No actuator or incomplete alignment (universal coding)

            The red light is on for 1 second and then flashes twice (alternately).

            Yes/No.

            break

            No actuator or incomplete alignment (unique code)

            Red light flashing at 4Hz

            effective

            break

            Output overload

            Green light flashes at 1Hz.

            be invalid

            break

            No input signal (dual output is not applicable)

            The green light is always on

            effective

            through

            Induction is normal

            Alternate flashing of traffic lights

            effective

            break

            Label is not registered.


            Related Products
            Download
            PDF file download
            Video file download
            Previous

            Contact us

            400-881-6062

            Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

            E-Mail: info@lh-safety.com

            Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

            (Greenland East Coast International Plaza-Room A 313)

            Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

            Online service

            Online message

          1. Click to refresh